Maintenance regulations for cold isostatic presses
When there is pressure in the cylinder, any maintenance and repair equipment is prohibited. The pressure relief in the cylinder must be completed before troubleshooting and treatment. **The following actions are prohibited:
1. When there is pressure in the cylinder, the high-pressure pipe leaks for pre-tensioning high-pressure pipe operation.
2. When there is pressure in the cylinder, disassemble the high-pressure pipe screw nut.
3. When there is pressure in the cylinder, it is forbidden to maintain the Supercharger.
4. When there is pressure in the cylinder, do not put your hand on the diameter of the valve body when repairing the integrated valve body2above the small hole in the millimeter.
5、When the high-pressure pipe leaks, wait for the pressure relief first, and then check the fault before repairing. High-voltage maintenance equipment is prohibited.
Cold isostatic press equipment operation regulations
1. When the equipment is working normally, unrelated personnel are prohibited from entering the working area.
2. It is forbidden for irrelevant personnel to open the electrical cabinet to prevent the risk of electric shock.
3. It is forbidden for irrelevant personnel to open the trunking, damaging the equipment lines and affecting the normal operation of the equipment.
4. When there are foreign objects in the cylinder, they should be fished out in time to prevent blocking the high-pressure holes or high-pressure pipelines, causing the equipment to be unable to relieve pressure normally.